Cảm biến lực Gicam R44
- Model: GICAM R44
- Hãng: Gicam
-
Cảm Biến Lực Trục Quay
Dãi đo: 100, 250, 500, 750, 1000 N
Ngõ ra: 1 mV/V
Nguồn cấp: Vcc 18 Max
Cảm biến lực Gicam, Cảm biến lực dạng mặt bích
Technical Specifications
Material |
Steel |
Nominal load |
100, 250, 500, 750, 1000 N |
Limit load |
400 % F.S. |
Breaking load |
500 % F.S. |
Nominal load deflection |
0,08 mm |
Supply voltage |
Maximum 18 V dc |
Sensitivity |
1 mV/V |
Output tollerance |
0,1 % F.S. |
Zero tollerance |
0,5 % F.S. |
Linearity |
0,1% F.S. |
Hysteresis |
0,03 % F.S. |
Reapeatability |
0,1 % F.S. |
Input resistance |
350-360 ohm |
Output resistance |
350-353 ohm |
Insulation resistance |
>= 2000 Mohm |
Creep (30 Minutes) |
0,03 % F.S. |
Thermal compensation |
-10 / +40°C (14 / +104°F) |
Operating temperature |
-20 / +70°C (-4 / +158°F) |
Temperature deviation zero |
0,003 % F.S. / °C |
Temperature deviation full scale |
0,002 % F.S. / °C |
Protection class |
IP 54 |
Connection |
Panel male connector UTS08E4P |
Standard cable length |
Loose female connector UTS6JC8E4S, connection cable 4 x 0,25 (length to be defined) |
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:Download PDF
Connections
Type |
CONNECTOR M8 RSMF 4/0.5M |
Length |
5 m (body lead cell not connected shield) |
Pin 1 |
+ IN |
Pin 2 |
- OUT |
Pin 3 |
- IN |
Pin 4 |
+ OUT |
MOUNTING OF THE LOAD CELL
General precautions to be followed in the installation and assembly of load cells:
- Follow the direction of application of force on the load cell
- Do not exceed the limits of the temperature as indicated in the data sheet
- Do not remove labels from the load cell
- Adequately protect the cables with sleeves or channels
- Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
- Do not carry out any welding on the mechanical structure after mounting the load cell
- Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
- In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
- Protect load cell from any dust accumulation with any appropriate means